Search by Keyword
Shopping Cart
Items: 0
Subtotal: $0.00
Note: All prices in US Dollars










Delivery Available

ALLEGRO LOGO

Allegro Venturi Blowers / Steel

Allegro Venturi Blowers / Steel
Click to enlarge image(s)

Venturi Blowers 

Operation

Compressed air or saturated steam is the power source for our Venturi Blower line. Small volumes of high velocity air (from the compressed air source) run through the casting and out the nozzle jets, creating a venturi action or pulling action that creates large volumes of air through the venturi and out the air diffuser.

A 1/2” hose with a “crows foot” connection is recommended from your air supply source to the side inlet connection. The compressor size required can be determined by checking the chart on air consumed at various inlet pressures. Operate this Venturi Blower on air or steam lines limited to 140 psi.

  • Lightweight construction
  • Convenient carry handles for one-person portability to any location
  • No guards required
  • Multiple inlet ports
  • Sturdy steel galvanized steel diffuser
  • All models include a crow’s foot inlet connection
  • Static ground is attached to the base of all blowers
  • Single piece cast aluminum inlet housing 

S P E C I F I C A T I O N S
Part Number
Overall
Length
Diameter
of Base
Diameter
Top of Horn
NPT Size
Bolt Circle
Diameter
Bolt Circle
Diameter
Net
Weight

9518-03S
 16.75"
7.31"
6.0"
1/2"
6.56"
0.4
5.5 lbs.
9518-03
30.5"
 7.31"
7.0"
1/2"
 6.56"
0.4
8.5 lbs.
9518-06
44.25"
 11.25"
12.5"
 1"
10.50"
0.4
22.3 lbs.
9518-08
 46.06"
 14.37"
 14.25"
 1"
13.62"
0.5
36.0 lbs.
9518-10
 48.00"
 17.50"
 15.75"
 1"
15.50"
0.6
42.0 lbs.

A I R F L O W
Inlet Pressure
40 PSIG
60 PSIG
80 PSIG

Part No.
AIR CONSUMED:

9518-03S
36 SCFM
50 SCFM
62 SCFM
9518-03
36 SCFM
50 SCFM
62 SCFM
9518-06
73 SCFM
98 SCFM
124 SCFM
9518-08
114 SCFM
152 SCFM
193 SCFM
9518-10
194 SCFM
268 SCFM
405 SCFM
TOTAL AIR FLOW:
9518-03S
815 CFM
981 CFM
1182 CFM
9518-03
1017 CFM
1231 CFM
1482 CFM
9518-06
2385 CFM
2885 CFM
3347 CFM
9518-08
3152 CFM
4152 CFM
4929 CFM
9518-10
6200 CFM
7500 CFM
8500 CFM

See Also
Submit a Review...

Allegro Venturi Blowers / Plastic

Allegro Venturi Blowers / Plastic
Click to enlarge image(s)

Plastic Venturi Blowers 

Operation

Compressed air or saturated steam is the power source for our Venturi Blower line. Small volumes of high velocity air (from the compressed air source) run through the casting and out the nozzle jets, creating a venturi action or pulling action that creates large volumes of air through the venturi and out the air diffuser.

A 1/2” hose with a “crows foot” connection is recommended from your air supply source to the side inlet connection. The compressor size required can be determined by checking the chart on air consumed at various inlet pressures. Operate this Venturi Blower on air or steam lines limited to 140 psi.

  • Lightweight construction
  • Convenient carry handles for one-person portability to any location
  • No guards required
  • Multiple inlet ports
  • Sturdy steel galvanized steel diffuser
  • All models include a crow’s foot inlet connection
  • Static ground is attached to the base of all blowers
  • Single piece cast aluminum inlet housing

S P E C I F I C A T I O N S
Part Number
Overall
Length
Diameter
of Base
Diameter
Top of Horn
NPT Size
Bolt Circle
Diameter
Bolt Circle
Diameter
Net
Weight

9518-13S
 16.75"
7.31"
6.0"
1/2"
6.56"
0.4
4.4 lbs.
9518-13
30.5"
 7.31"
7.0"
1/2"
 6.56"
0.4
6.2 lbs.
9518-16
44.25"
 11.25"
12.5"
 1"
10.50"
0.4
14.9 lbs.
9518-18
 46.06"
 14.37"
 14.25"
 1"
13.62"
0.5
26.3 lbs.

A I R F L O W
Inlet Pressure
40 PSIG
60 PSIG
80 PSIG

Part No.
AIR CONSUMED:

9518-13S
36 SCFM
50 SCFM
62 SCFM
9518-13
36 SCFM
50 SCFM
62 SCFM
9518-16
73 SCFM
98 SCFM
124 SCFM
9518-18
114 SCFM
152 SCFM
193 SCFM
TOTAL AIR FLOW:
9518-13S
815 CFM
981 CFM
1182 CFM
9518-13
1017 CFM
1231 CFM
1482 CFM
9518-16
2385 CFM
2885 CFM
3347 CFM
9518-18
3152 CFM
4152 CFM
4929 CFM

See Also
Submit a Review...

Allegro Venturi Blower Ducting

Allegro Venturi Blower Ducting
Click to enlarge image(s)

Venturi Blower Ducting and Statically Conductive Duct

Lightweight, retractable and designed for maximum air handling capabilities. Dual direction flow with low friction loss while providing a safe positive means of discharging static build up.


Part Number
9500-15 -   15' of 8" Duct
9500-25 -    25' of 8" Duct
950015E-    15' of 8" Statically Conductive Duct 
950025EX-   25' of 8" Statically Conductive Duct
9600-15-   15' of 16" Duct
9600-25-   25' of 16" Duct
960015EX-   15' of 16" Statically Conductive Duct
960025EX-   25' of 16" Statically Conductive Duct

See Also
Submit a Review...

Welcome  ·  About Us  ·  Contact Us  ·  Shipping  ·  Privacy Policy  ·  Sitemap
Copyright © Metro Industrial Supply, LLC | Keyport, New Jersey 
Toll-Free 866-601-5552 / Fax 866-478-2110
info@metrosupplyllc.com